UltraTouch™ Denim Insulation delivers premium sound and thermal performance without the itch, chemicals, or mess of traditional insulation. Made from 80% post-consumer recycled natural cotton fibers, it’s safe to handle, eco-friendly, and built to last. With easy installation and a Class-A fire rating, UltraTouch is the smart choice for comfort, safety, and sustainability in any space.
--- OUT OF STOCK until Q3 2026 ---
Features
- No Itch, No Irritants – Safe to handle with bare hands, no fiberglass or chemical irritants
- Safe for Indoor Air Quality – No VOCs, formaldehyde, or off gassing
- Superior Sound Control – High NRC cotton will increase STC by 1-3 points over fiberglass batt insulation
- R-19 Insulation – Delivers maximum R-value for year-round comfort
- Class-A Fire Rated – Highest fire rating for building materials
- LEED Eligible – Eco-friendly 80% post-consumer recycled denim and cotton fibers
- Easy Installation – Oversized widths and perforated batts make fitting quick and simple
- Proudly made in the USA
Couldn't load pickup availability
Specs
Specs
| Dimensions | 16.25" x 94" per batt |
| Batt Thickness | 5.5" |
| Sq Ft per Bag | 53.04 sq ft |
| Batts per Bag | 5 batts per bag (40 per pallet) |
| Bags per Pallet | 8 bags per pallet (424.32 sq ft) |
| Weight | 30 lbs/bag (6 lbs/batt) |
| R-Value | R-19 batt |
| Framing | Fits best in 6" 16" o.c. metal framing |
| Easy-Tear Perforation | Per full bag, minimum 2 perforated batts |
| Itch & Irritation | None |
| Installation Method | Friction Fit |
Material Testing
Material Testing
Noise Reduction Coefficient
| Frequency (Hz) | 125 | 250 | 500 | 1000 | 2000 | 4000 | NRC |
| R-13 UltraTouch Denim Insulation | 0.95 | 1.30 | 1.19 | 1.08 | 1.02 | 1.00 | 1.15 |
| R-19 UltraTouch Denim Insulation | 0.97 | 1.37 | 1.23 | 1.05 | 1.00 | 1.01 | 1.15 |
| Tested Properties | Testing Method | Performance |
|---|---|---|
| Trade Certifications | BOCA, CABO, ICBO, LEED, SBCCI | |
| R-Value | ASTM C518 | R-19 per 5.5" batt |
| Fire Rating | ASTM E84 UL-723 | Class A |
| Fire Test of Building Material | ASTM E119 UL263 | Pass (1 hour) |
| Fungal Resistance | ASTM C739 | Pass |
| Bacteria Resistance | ASTM C739 | Pass |
| Moisture Absorption | ASTM C739 | Pass |
| VOC | CDPH 01350 | Pass |
Installation Instructions
Installation Instructions
- Calculate Needed Insulation - As a general rule, to calculate how much insulation you need, multiply the total square footage of the walls by 85% for 16" O.C. framing and 90% for 24" O.C. framing.
- Prepare the Insulation - Shake each batt after removing it from the packaging to help the fibers rebound from compression. Full rebound may take several days, depending on conditions.
- Fit Between Studs - Place each batt firmly into standard 16″ O.C. or 24″ O.C. framing cavities. For off-size cavities, tear along a perforation or cut to size, making pieces about 0.5″ wider and longer than the cavity.
- Cut or Tear Around Obstacles - Create snug fits around plumbing, vent lines, electrical boxes, and other obstructions. Use leftover pieces to fill small gaps around windows, doors, or irregular spaces.
- Install Vapor Barrier if Required - Check local building codes for vapor barrier requirements. If needed, apply a permeable barrier toward the living area after insulation is installed. For exterior walls, a single continuous vapor retarder is preferred over multiple faced batts.
- Install UltraTouch:
- Walls - Insert batt between studs and tuck in for a tight friction fit. About 30% of batts are perforated for quick sizing adjustments.
- Ceilings - Layer batts to reach desired R-value, alternating the direction of each layer. Secure with wire or mesh until drywall is installed.
- Floors & Crawl Spaces - Secure insulation to joists using wire or mesh. In crawl spaces, install vapor barriers over bare ground and on cavity faces (toward the warm side of the subfloor) before installing insulation.
Common Product Uses
Common Product Uses
| Type of Space | Use Case |
|---|---|
| Interior Walls | Reducing room-to-room noise |
| Exterior Walls | Thermal efficiency and outdoor noise reduction |
| Recording Studio | Acoustic treatment and sound isolation |
| Office and Retail | Install above drop ceiling tiles or to improve wall assemblies |
| Industrial | Cost-effective absorption for large rooms |
Resources
Installation Guides
Spec Sheets
Architect CSI Specs